| Micro Motion F050P Coriolis Meter | 1/2 Inch (DN15), 316L Stainless Steel, High Pressure |
| Mass Flow Accuracy (Liquid) | ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional) |
| Mass Flow Repeatability (Liquid) | ±0.050% of rate |
| Volume Flow Accuracy (Liquid) | ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional) |
| Volume Flow Repeatability (Liquid) | ±0.050% of rate |
| Mass Flow Accuracy (Gas) | ±0.5% of rate |
| Mass Flow Repeatability (Gas) | ±0.25% of rate |
| Density Accuracy (Liquid) | ±0.002 g/cm³ (2.0 kg/m³) (standard), ±0.001 g/cm³ (1.0 kg/m³) (optional) |
| Temperature Accuracy | ±1 °C ±0.5% of reading |
| Max Working Pressure | 5,000 psig (344 barg) |
| Approvals and Certifications | UL, CSA, IECEx, NEPSI, ATEX, Ingress Protection, EMC effects |
| Micro Motion 1700 Single Variable Field Mount Flow Transmitter | |
| Output Variables | Mass flow, Volume flow |
| Local Display | Standard user interface with 2-line LCD panel |
| Optical Switches | Two optical switches for local operation |
| Power Supply | Self-switching AC/DC input, 85 to 265 VAC, 18 to 100 VDC, 6 watts typical, 11 watts maximum |
| Input/Output Signals | One active 4–20 mA output, One active frequency output |
| Mounting Options | Field-mount, integrally mounted to a Micro Motion sensor, Remotely mounted to any 4-wire or 9-wire Micro Motion sensor |
| Application Types | Continuous process control, Two-phase flow/entrained gas, Meter verification |
| Hazardous Approvals | Class I, Div. 1, Class I, Div. 2, Zone 1, Zone 2 |

Rosemount
YokoGawa
ABB
E+H
HoneyWell
Micro Motion Coriolis
Rosemount
Yokogawa