Micro Motion F050P Coriolis Meter | 1/2 Inch (DN15), 316L Stainless Steel, High Pressure |
Mass Flow Accuracy (Liquid) | ±0.20% of rate (standard) ±0.15% of rate (optional) ±0.10% of rate (optional) |
Mass Flow Repeatability (Liquid) | ±0.050% of rate |
Volume Flow Accuracy (Liquid) | ±0.20% of rate (standard) ±0.15% of rate (optional) ±0.10% of rate (optional) |
Volume Flow Repeatability (Liquid) | ±0.050% of rate |
Mass Flow Accuracy (Gas) | ±0.5% of rate |
Mass Flow Repeatability (Gas) | ±0.25% of rate |
Density Accuracy (Liquid) | ±0.002 g/cm³ (2.0 kg/m³) (standard) ±0.001 g/cm³ (1.0 kg/m³) (optional) |
Temperature Accuracy | ±1 °C ±0.5% of reading |
Sensor Maximum Working Pressure | 5,000 psig (344 barg) |
Meter Approvals | UL, CSA, IECEx, NEPSI, ATEX, Ingress Protection, EMC effects |
Micro Motion 2400S Compact, Integral-Mount Transmitter | |
Output Variables | Mass & volume flow, net product content/flow, temperature, density, concentration |
Local Display | Standard user interface with 2-line LCD panel |
Power | Self-switching AC/DC input, automatically recognizes supply voltage 85–265 VAC, 50/60 Hz, 4 watts typical, 7 watts maximum 18–100 VDC, 4 watts typical, 7 watts maximum |
Input/Output Signals (Analog Output Option) | Channel A: One active 4–20 mA output (not intrinsically safe) Channel B (configurable): One active or passive frequency output, one active or passive discrete output, one active or passive discrete input |
Input/Output Signals (PROFIBUS-DP Option) | Digital 2-way PROFIBUS-DP signal |
Input/Output Signals (DeviceNet Option) | Digital 2-way DeviceNet signal (Now Obsolete) |
HART | Bell 202 signal is superimposed on the primary milliamp output HART communication is not available on PROFIBUS-DP and DeviceNet transmitter versions |
Mounting Options | Field mount, integral with sensor |
Application Types | Continuous process control, two-phase flow/entrained gas, meter verification |
Hazardous Approvals | C1D2, Zone 2 |