Micro Motion F050P Coriolis Meter | 1/2 Inch (DN15), 316L Stainless Steel, High Pressure |
Mass Flow Accuracy (Liquid) | ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional) |
Mass Flow Repeatability (Liquid) | ±0.050% of rate |
Volume Flow Accuracy (Liquid) | ±0.20% of rate (standard), ±0.15% of rate (optional), ±0.10% of rate (optional) |
Volume Flow Repeatability (Liquid) | ±0.050% of rate |
Mass Flow Accuracy (Gas) | ±0.5% of rate |
Mass Flow Repeatability (Gas) | ±0.25% of rate |
Density Accuracy (Liquid) | ±0.002 g/cm³ (2.0 kg/m³) (standard), ±0.001 g/cm³ (1.0 kg/m³) (optional) |
Temperature Accuracy | ±1 °C ±0.5% of reading |
Sensor Maximum Working Pressure | 5,000 psig (344 barg) |
Meter Approvals | UL, CSA, IECEx, NEPSI, ATEX, Ingress Protection, EMC effects |
Micro Motion 3700 Controller And Transmitter | Remote Field-Mount |
Output Variables | Mass & volume flow, Net product content / flow, Temperature, Density, Concentration |
Local Display | Multi-line LCD panel, Backlit LCD, 128 × 128 pixel |
Power | AC option: 85 to 265 VAC, 50/60 Hz, 30 VA DC option: 18 to 30 VDC, 18 watts typical, 25 watts maximum |
Input/Output Signals | Two active 4–20 mA, Three discrete outputs, One 2-wire frequency output, One 2-wire frequency input, Two discrete momentary inputs |
Mounting Options | Remote field-mount |
Application Types | Batch controller, Custody transfer, Two-phase flow/entrained gas, Meter verification |
Hazardous Approvals | UL, CSA, ATEX, NEPSI |