| Specification | Details |
|---|---|
| Micro Motion H400F Hygienic Coriolis Meter | 4 Inch (DN100), 316L Stainless Steel, 15 RA Finish |
| Mass Flow Accuracy (Liquid) | Up to ±0.05% of rate |
| Mass Flow Repeatability (Liquid) | Up to ±0.025% of rate |
| Volume Flow Accuracy (Liquid) | Up to ±0.05% of rate |
| Volume Flow Repeatability (Liquid) | Up to ±0.025% of rate |
| Mass Flow Accuracy (Gas) | Up to ±0.35% of rate |
| Mass Flow Repeatability (Gas) | Up to ±0.175% of rate |
| Density Accuracy (Liquid) | Up to ±0.0005 g/cm³ (±0.5 kg/m³) |
| Temperature Accuracy | ±1 °C ±0.5% of reading |
| Maximum Working Pressure | 1,450 psig (100 barg) |
| Meter Approvals, Calibrations, and Certifications | • CSA • IECEx • ATEX |
| Micro Motion 2500 Compact Control Room Multivariable Flow And Density Transmitter | None |
| Output Variables | • Mass & volume flow • Net product content / flow • Temperature • Density • Concentration |
| Local Display | None |
| Power | Minimum 19.2 to 28.8 VDC 6.3 watts Meets Installation (Overvoltage) Category II, Pollution Degree 2 requirements |
| Input/Output Signals | • One active 4–20 mA output • One active frequency output |
| HART | Bell 202 signal superimposed on the primary milliamp output |
| Mounting Options | • Mounted on 35 mm rail • Rail must be grounded |
| Application Types | • Continuous process control • Two-phase flow/entrained gas • Meter verification |
| Hazardous Approvals | Suitable for non-hazardous environments only |

Rosemount
YokoGawa
ABB
E+H
HoneyWell
Micro Motion Coriolis
Rosemount
Yokogawa