Specification | Details |
---|---|
Micro Motion H400S Hygienic Coriolis Meter | 4 Inch (DN100), 316L Stainless Steel, 32 RA Finish |
Mass Flow Accuracy (Liquid) | Up to ±0.05% of rate |
Mass Flow Repeatability (Liquid) | Up to ±0.025% of rate |
Volume Flow Accuracy (Liquid) | Up to ±0.05% of rate |
Volume Flow Repeatability (Liquid) | Up to ±0.025% of rate |
Mass Flow Accuracy (Gas) | Up to ±0.35% of rate |
Mass Flow Repeatability (Gas) | Up to ±0.175% of rate |
Density Accuracy (Liquid) | Up to ±0.0005 g/cm³ (±0.5 kg/m³) |
Temperature Accuracy | ±1 °C ±0.5% of reading |
Maximum Working Pressure | 1,450 psig (100 barg) |
Micro Motion 2700 Field And Integral-Mount Multivariable Flow And Density Transmitter | |
Output Variables | • Mass & volume flow • Net product content / flow • Temperature • Density • Concentration |
Local Display | Standard user interface with 2-line LCD panel Two optical switches for local operation Glass or plastic lens options |
Power | Self-switching AC/DC input, automatically recognizes supply voltage 85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum 18 to 100 VDC, 6 watts typical, 11 watts maximum Complies with low voltage directive 2006/95/EC |
Input/Output Signals | Not intrinsically safe • One active 4–20 mA output • One active frequency output (configurable as discrete output) Intrinsically safe option available |
Mounting Options | Field-mount Integrally mounted to Micro Motion sensors Remotely mounted to any 4-wire or 9-wire Coriolis sensor |
Application Types | Continuous process control Custody transfer Two-phase flow/entrained gas Meter verification |
Hazardous Approvals | Class I, Div. 1 Class I, Div. 2 Zone 1 Zone 2 |