Specifications
Rosemount MS Magnetic Sensor MS100 for Slurry Applications, 10 inch (DN250) | |
Reference Accuracy | ±0.25% with optional ±0.15% high accuracy |
Line Size | 3” (80mm) to 36” (900mm) |
Liner Material Options | PTFE, PFA+, Polyurethane, Neoprene, Linatex Natural Rubber, Adiprene |
Electrode Options | Material: 316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium
Type: Standard, Bullet, Flat Optional 3rd electrode for grounding |
Flange Options | Connections: Slip-on, weld-neck, grooved coupling
Ratings: ASME Class 150 – 2500, EN-1092 PN10 – PN40, AS2129 Table D and E, JIS B2220 10K – 40K, AS4087 PN16 – PN35 Materials: Carbon Steel, 304/304L SST, 316/316L SST Additional flange ratings and materials may be available upon request |
Approvals | Ordinary Locations
Higher level approvals include Intrinsically Safe Electrodes |
Enclosure Type | Type 4X |
Compatibility | 8782 Slurry Transmitter for optimum performance in high noise applications
8712EM and 8732EM (remote mount only) for standard magnetic flow meter performance |
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters | |
Sensor compatibility | Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers. |
Transmitter coil drive current | 500mA |
Flow rate range | Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s). |
Conductivity limits | Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater. |
Power supply | 90 – 250VAC, 50/60Hz or 12 – 42VDC |
Line power fuses | 90-250VAC systems
<li |