Specifications
Rosemount 8721040 Hygienic Magnetic Flow Meter Sensor | |
---|---|
Accuracy | |
Up to 0.25% of volumetric flow rate accuracy over 13:1 flow turndowns, 0.5% over 40:1 flow turndown | |
Line Sizes | ½-4 inch (15-100 mm) |
Liner Materials | PFA |
Electrode Materials | 316L Stainless Steel, Nickel Alloy, Platinum |
Process Connections | Tri-Clamp® Sanitary Coupling IDF Sanitary Coupling (screw type) Weld Nipple DIN 11851 (Imperial and Metric) DIN 11864 (-1 and -2 Form A) SMS 1145 DEN US 50 Weld Nipple |
Product Certifications | 3-A, EHEDG Type EL, PMO (M-b-350) |
Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters | |
---|---|
Sensor compatibility | |
Compatible with Rosemount 8705, 8711, and 8721 sensors. Compatible with AC and DC powered sensors of other manufacturers. | |
Transmitter coil drive current | 500mA |
Flow rate range | Capable of processing signals from fluids that are traveling between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s). |
Conductivity limits | Process liquid must have a conductivity of 5 microSiemens/cm (5 micromhos/cm) or greater. |
Power supply | 90 – 250VAC, 50/60Hz or 12 – 42VDC |
Line power fuses | 90-250VAC systems: 1A, 250V, I2t, 1.5 A2s Rating, Fast Acting Bussman AGC-1, Littlefuse 31201.5HXP 12-42VDC systems: 3 Amp, 250V, I2t, 14 A2s Rating, Fast Acting Bel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135 |
Line power fuses | 15W maximum – DC 40VA maximum – AC |
Switch-on current | AC: Maximum 35.7A (< 5ms) at 250VAC DC: Maximum 42A (< 5ms) at 42VDC |