Specifications | Rosemount MS Magnetic Sensor MS080 |
---|---|
Reference Accuracy | ±0.25% with optional ±0.15% high accuracy |
Line Size | 3” (80mm) to 36” (900mm) |
Liner Material Options | PTFE, PFA+, Polyurethane, Neoprene, Linatex Natural Rubber, Adiprene |
Electrode Options | Material: 316L Stainless Steel, Nickel Alloy, Platinum, Tantalum, Titanium Type: Standard, Bullet, Flat Optional 3rd electrode for grounding |
Flange Options | Connections: Slip-on, weld-neck, grooved coupling Ratings: ASME Class 150 – 2500, EN-1092 PN10 – PN40, AS2129 Table D and E, JIS B2220 10K – 40K, AS4087 PN16 – PN35 Materials: Carbon Steel, 304/304L SST, 316/316L SST Additional flange ratings and materials may be available upon request |
Approvals | Ordinary Locations ATEX Non-Sparking; Dust Class I Div 2; Dust Class I Zone 2; Dust IECEx Non-Sparking; Dust ATEX increased safety; Dust Class I Zone1; Dust IECEx Increase Safety; Dust Higher level approvals include Intrinsically Safe Electrodes |
Enclosure Type | Type 4X IP66, IP67, IP68, IP73 |
Specifications | Rosemount 8712E Magnetic Flow Meter Transmitter |
---|---|
Accuracy | Up to ±0.15% of volumetric flow rate accuracy over 13:1 flow turndowns, ±0.25% over 40:1 flow turndown. |
Diagnostic | In Situ Meter Verification, Grounding & Wiring Fault Detection, High Process Noise Detection, Tunable Empty Pipe Detection, Transmitter Fault Detection, Sensor Fault Detection |
Compatibility | All Rosemount manufactured Sensors: 8705, 8711, 8721, 8707 Universal capabilities allow E-Series transmitters to be compatible with AC and DC powered sensors from other manufacturers. |
Power Supply | 90-250 VAC, 50-60 Hz or 12-42 VDC. |
Power consumption | 15 W maximum – DC 40 VA maximum – AC |
Enclosure Rating | 8712E: Type 4x, IP66 |