1. What is a Rosemount PT100?
The Rosemount PT100 is a platinum resistance temperature detector (RTD) manufactured by Emerson’s Rosemount brand, designed for high-accuracy temperature measurement in industrial processes.
- Key Features:
- PT100 Principle: 100Ω at 0°C, with linear resistance change as temperature varies (e.g., 138.5Ω at 100°C).
- Accuracy Class: Class A (±0.15°C at 0°C) or Class B (±0.3°C at 0°C).
- Industrial Certifications: ATEX, IECEx, SIL 2/3 (for hazardous areas).
2. Key Advantages of Rosemount PT100 Sensors
2.1 High Accuracy & Long-Term Stability
- Superior linearity compared to thermocouples, ideal for ±0.1°C precision in pharmaceuticals and food processing.
- Advanced platinum wire coating minimizes oxidation, ensuring long-term reliability.
2.2 Rugged Industrial Design
- Protection Rating: IP67/IP68 (dustproof/waterproof).
- Vibration Resistance: Tested up to 10G (suitable for oil & gas applications).
- Wetted Materials: 316L stainless steel, Hastelloy (corrosion-resistant).
2.3 Flexible Signal Output Options
- Direct resistance output (2/3/4-wire configurations to reduce lead errors).
- Integrated transmitters (e.g., Rosemount 214C with 4-20mA + HART/FF protocols).
3. Popular Models & Applications
Model | Key Features | Industry Applications |
---|---|---|
Rosemount 214C | With transmitter, HART comms | Chemical, energy (pipeline/reactors) |
Rosemount 0085 | Sanitary, EHEDG/FDA compliant | Pharma, food & beverage |
Rosemount 64 | High-temperature design | Metallurgy, glass manufacturing |
4. How to Select the Right Rosemount PT100?
- 4.1 Define Requirements:
- Temperature range, accuracy class (A/B), mounting type (threaded/flange/sanitary clamp).
- Need a transmitter? Output signal type (4-20mA/RS485/HART)?
- 4.2 Environmental Factors:
- Corrosive media → Choose Hastelloy material.
- Explosive atmospheres → Select ATEX-certified models.
5. Why Choose Rosemount PT100?
- Global Support: Emerson provides local calibration & technical assistance.
- Traceability: Each sensor has a unique serial number with ISO 17025 calibration certificates.
- Seamless Integration: Compatible with Rosemount DCS systems (e.g., DeltaV).
6. Frequently Asked Questions (FAQ)
Q1: PT100 vs. Thermocouple – Which to Choose?
- PT100: Best for mid/low temps + high accuracy.
- Thermocouple: Better for extreme temps (>600°C) but less precise.
Q2: What is the Calibration Interval for Rosemount PT100?
- Recommended 1-2 years (per IEC 60751), shorter in harsh environments.
Need help selecting the right Rosemount PT100? Contact our engineers for a free consultation and product datasheets!